About Us
Managed by technocrats with hands-on experience in transformer design, development, production, quality control and field servicing.
Company ProfileManaged by technocrats with hands-on experience in transformer design, development, production, quality control and field servicing.
Company ProfileDedicated manufacturing plant at MIDC Rabale, Navi Mumbai, with in-house testing including lightning impulse tests to IS, IEC & ANSI.
Quality & TestingQuality management, service call handling, inventory control and transparent project reporting from order to commissioning.
Get SupportURJA designs and builds oil-immersed and dry type transformers for utilities, EPC contractors and heavy industry. Every unit is engineered in-house to the buyer's specification — rating, voltage ratio, vector group, cooling and site conditions — rather than adapted from a catalogue.
Our product line covers converter duty, distribution, power, furnace, neutral earthing, hermetically sealed and reactor transformers, cast resin and VPI dry type transformers and unitized compact substations.
Custom-built for utilities, refineries, steel plants, infrastructure and commercial buildings — each with full routine test reports.
Final-stage step-down transformers that convert distribution line voltage to the utilisation level used by industrial estates, utilities and buildings.
Inner and outer LV winding sections built from pancake coils with the HV winding between them, for robust short-circuit performance.
Zig-zag (interstar) winding creates a neutral point with the required zero-sequence impedance for earth-fault protection in 3-phase systems.
No conservator — the insulating oil is fully sealed from the atmosphere, reducing oxidation, moisture ingress and routine maintenance.
Variable transformer-reactor with two core elements on a common yoke and a primary winding split into independently fed phase sets.
Designed, assembled, wired and operationally tested in our works — including power factor correction equipment — so site work is minimal.
Iron core with vacuum pressure impregnated HV and LV windings — an oil-free solution for clean indoor industrial installations.
Primary and secondary windings fully encapsulated in epoxy resin to block moisture — for indoor and outdoor, fire-sensitive locations.
Engineered for rectifier loads, harmonics, high currents and frequent switching in metals, chemicals and process industries.
A quick reference used by our design engineers when EPC contractors and plant buyers send their first enquiry.
| Application / Site Condition | Recommended Type | Why It Fits |
|---|---|---|
| Utility networks, industrial estates, commercial LV supply | Distribution Transformer | Final step-down to consumer voltage with proven, economical oil-immersed design. |
| Plant main intake, refineries, steel & power plants up to 10 MVA, 33 kV | Power Transformer | Short-circuit strength verified by type tests at CPRI & ERDA. |
| Rectifiers, DC drives, electrolysis, traction supplies | Converter Duty Transformer | Windings and cooling designed for harmonic-rich, non-sinusoidal loading. |
| Arc and induction furnaces, smelting | Furnace Transformer | Built for very high secondary current and frequent switching cycles. |
| Delta or ungrounded systems needing earth-fault detection | Neutral Earthing Transformer | Zig-zag winding provides an artificial neutral with low zero-sequence impedance. |
| Remote, humid or dusty sites with limited maintenance | Hermetically Sealed Transformer | Sealed tank keeps oil away from air and moisture; no breather to service. |
| Hospitals, high-rise buildings, data centres, tunnels | Cast Resin Dry Type | Oil-free, epoxy-encapsulated windings for fire-sensitive and humid indoor areas. |
| Clean indoor industrial substations | VPI Dry Type | Oil-free VPI insulation with simple installation close to the load. |
| Fast-track projects, temporary or space-limited sites | Unitized Compact Substation | Factory assembled, wired and tested; minimal civil and site work. |
| Voltage regulation, current limiting, motor starting | Reactor Transformer | Variable reactance from split, independently fed primary winding sets. |
Not sure which design suits your project? Share your single-line diagram and site data with our engineering team via the Contact Page
Independent test certificates, documented quality procedures and references from real installations.
Dynamic short-circuit withstand tests up to 10 MVA, 33 kV at CPRI & ERDA — India's national testing authorities.
Awards & RecognitionOne engineering team, multiple standards — specifications aligned to your project, consultant or utility.
Quality PolicyIn-house design for special ratios, vector groups and duties. An 8000 kVA, 33/6.6 kV unit was delivered in 80 days.
Client References
See core building, winding, assembly and testing of power transformers at our Navi Mumbai plant.
Feedback from refineries, steel producers, EPC firms and international project owners who operate URJA transformers.
Practical answers for procurement managers and consultants evaluating an Indian transformer supplier.
URJA designs and manufactures transformers up to 10 MVA in the 33 kV voltage class. Units in this range have been type tested for dynamic short-circuit withstand at CPRI and ERDA, with lightning impulse tests carried out in our own laboratory.
Transformers are designed, manufactured and tested as per IS, IEC and ANSI standards, so the same design approach can be specified for Indian, Middle Eastern, African and Asian projects.
Yes. We supply buyers in the UAE, Saudi Arabia, Kenya, Nigeria, South Africa and Tanzania, and have delivered cast resin dry type transformers for a project in Indonesia, including complete vendor documentation.
Cast resin transformers fully encapsulate the windings in epoxy, blocking moisture — ideal for humid, fire-sensitive or outdoor locations. VPI transformers use vacuum pressure impregnated windings and suit clean indoor industrial environments.
Choose a hermetically sealed design where maintenance access is limited or the atmosphere is humid or dusty. With no conservator, the oil never contacts air, which slows oxidation and moisture absorption.